How to Choose Flame-Resistant Clothing
Flame-resistant (FR) clothing does not catch fire easily, and when the flame is removed it stops burning by itself. That buys the wearer the seconds needed to escape — but it does not make the wearer fireproof, and it does not protect against heat beyond its rating. Choosing FR clothing means matching the garment's rating to the heat and flame the job actually produces. This guide explains the standards, the code letters, and what to check before you order.
EN ISO 11612: the code letters
EN ISO 11612 is the European standard for clothing that protects against heat and flame. A garment certified to it carries code letters, and each letter covers a different hazard:
- A — flame spread: A1 is surface ignition, A2 is edge ignition.
- B — convective heat, from hot gases and flames.
- C — radiant heat.
- D — molten aluminium splash.
- E — molten iron splash.
- F — contact heat.
Each letter carries a performance level — the higher the number, the greater the protection. A garment is only certified for the letters printed on its label, so check the label rather than assuming a garment covers every hazard. The Portwest FR21 coverall, for example, is certified to EN ISO 11612 (A1+A2, B1, C1, F1) and to EN 1149-5 for antistatic protection — a lightweight 210 g coverall for general flame-resistant work.
EN ISO 11611 and antistatic protection
EN ISO 11611 covers protective clothing for welding and allied processes, with two classes: Class 1 for lighter welding work and Class 2 for heavier spatter and more intense radiant heat. A garment can be certified to both EN ISO 11612 and EN ISO 11611 — the FR21's range, for instance, is built for welding as well as general flame-resistant work. Where static is also a risk, look for EN 1149-5 antistatic certification on the same garment: a spark from static discharge can ignite a flammable atmosphere, so the two protections often go together.
Fabric weight and insulation
Fabric weight is the simplest guide to what a garment is for. Lightweight FR fabric, around 210 g as in the FR21, is cooler and more comfortable for hot work and long shifts. Heavier fabric gives more protection and more insulation: the Portwest FR59 is an insulated FR jacket for cold-weather flame-resistant work, and the FR84 is a winter FR coverall for the same conditions. Inherent FR fibres, such as aramid, keep their flame resistance for the life of the garment. Treated cotton is flame-resistant because of a chemical treatment, so it needs proper care — follow the care label, and avoid fabric softener and bleach, which can reduce the treatment.
What FR clothing does not do
Three common misunderstandings are worth clearing up. First, EN ISO 11612 is not an arc-flash standard: protection against electric arc is covered by a different standard, IEC 61482, and a garment certified only to EN ISO 11612 should not be assumed to protect against arc flash. Second, flame resistance is not chemical protection — a splash of solvent will still soak through an FR coverall. Third, the garment only protects the skin it covers: wear it fully closed, with cuffs over gloves and trousers over boots, and do not wear meltable synthetic underlayers beneath it — underlayers should be flame-resistant or natural fibres, so they do not melt onto the skin in a flash.
Fit, care and replacement
FR clothing should fit loosely enough to trap a layer of air — that air is part of the insulation — but not so loosely that it catches on equipment. Check the size chart against body measurements, not against normal clothing sizes. Inspect garments regularly: replace them when they are worn thin, torn, or contaminated with oil or grease, because contamination can compromise the flame resistance. Wash as the care label directs, and keep FR garments separate from ordinary workwear so the treatment is not damaged in the wash. Browse the range in our protective clothing category or the Portwest brand page.
Need a quotation? Tell us the product, the quantity and the destination country, and we will come back with a clear price. Send an inquiry or message us on WhatsApp.
Frequently asked questions
- What do the letters in EN ISO 11612 mean?
- A is flame spread, B is convective heat, C is radiant heat, D is molten aluminium splash, E is molten iron splash, and F is contact heat. Each letter carries a performance level — the higher the number, the greater the protection. A garment is only certified for the letters printed on its label.
- What is the difference between EN ISO 11612 and EN ISO 11611?
- EN ISO 11612 covers heat and flame in general — foundries, petrochemical plants and similar work. EN ISO 11611 covers welding and allied processes specifically, with two classes: Class 1 for lighter welding work and Class 2 for heavier spatter. A garment can be certified to both standards.
- Does flame-resistant clothing stop burns?
- No. Flame-resistant clothing resists ignition and self-extinguishes when the flame is removed, which gives the wearer time to escape. It does not make the wearer fireproof, and it does not protect against heat that exceeds its rating — which is why the right rating for the job matters.
- How should FR clothing be washed?
- Follow the care label on the garment. On treated cotton, fabric softener and bleach can reduce the flame-resistant treatment, so they should be avoided. Inspect the garment regularly and replace it when it is worn thin, torn or contaminated with oil or grease.
More guides
- How to Choose Chemical Protective Coveralls →
- EN 388 Glove Ratings Explained (4X42C) →
- N95 vs FFP2 vs KN95: What's the Difference? →
- Choosing a Half-Mask Respirator & Filters →
- Earplugs vs Earmuffs: Hearing Protection →
- Full-Face vs Half-Mask Respirators →
- 3M Gas Cartridges: 6001, 6003, 6006, 60923, 60926 →
- How to Choose Chemical-Resistant Gloves →
- How to Choose Safety Footwear (S1P / S3) →