Skip to main content
WAYTO TRADE CO., LIMITED logo

3M Gas Cartridges: 6001, 6003, 6006, 60923, 60926

A gas cartridge cleans the air by adsorption: activated carbon inside the cartridge traps gas and vapour molecules as air passes through. The wrong cartridge traps nothing — the gas passes straight through and the wearer breathes it in. So choosing a cartridge is a matching exercise: match the cartridge to the gas. This guide compares the five 3M cartridges buyers ask for most.

The five cartridges at a glance

CartridgeProtects againstParticulate filter built in?
6001Organic vapoursNo — gas only
6003Organic vapours, acid gasesNo — gas only
6006Organic vapours, acid gases, ammonia, formaldehyde (multi-gas)No — gas only
60923Organic vapours, acid gasesYes — P100
60926Organic vapours, acid gases, ammonia, formaldehyde (multi-gas, A1B1E1K1P3)Yes — P100

The 3M 6001 is the organic vapour cartridge — for solvents and similar vapours, the most common cartridge of all. The 3M 6003 adds acid gases to the same organic vapour protection. The 3M 6006 is the multi-gas cartridge: organic vapours, acid gases, ammonia and formaldehyde in one unit. The 60923 and the 3M 60926 are combination filters — the same gas protection as the 6003 and the 6006 respectively, with a P100 particulate filter built in. The 60926 is rated A1B1E1K1P3: the letters stand for organic vapours (A), inorganic gases (B), acid gases (E) and ammonia (K), class 1, plus P3 particulate protection.

Gas only, or gas plus dust?

Gas cartridges do not filter dust. Where dust, mist or paint spray is also present, a gas-only cartridge such as the 6001, 6003 or 6006 must be paired with a particulate pre-filter. The combination filters solve this in one unit: the 60923 pairs organic vapour and acid gas protection with a P100 filter, and the 60926 pairs multi-gas protection with a P100 filter. One unit instead of two means fewer parts to stock and no chance of forgetting the pre-filter — but the combination unit is heavier and bulkier, so for gas-only work the plain cartridge is the lighter choice.

6003 or 6003CN?

3M cartridges are made in market-specific versions. The 6003CN is the China-market version of the cartridge — a different listing for the China market, not the same product as the international 6003. The same applies across the range: order by the exact model for your market, and check the marking on the cartridge and its packaging before you accept the goods. If the model on the box does not match the model you ordered, do not accept it.

How to choose

Start from the safety data sheet of the chemical involved and match the cartridge to the hazards it lists:

  • Solvents, thinners or spray painting on their own — an organic vapour cartridge such as the 6001, with a particulate pre-filter for the paint mist.
  • Acid gases also present, such as hydrogen chloride or sulphur dioxide — the 6003, or the 60923 where dust is also present.
  • Ammonia or formaldehyde in the mix — the multi-gas 6006, or the 60926 where dust is also present.
  • Hazard unknown — do not guess. Identify the chemical first, then choose the cartridge.

All five cartridges use the 3M bayonet connection, so they fit both the 6000 series half-masks (6100/6200/6300) and the 6000 series full-face masks (6700/6800/6900). The protection factor depends on the facepiece and the fit test, not on the cartridge alone — up to 10 times the exposure limit with a half-mask, and up to 50 times with a fit-tested full-face mask. Browse the range in our respiratory protection category or the 3M brand page.

Service life and replacement

Gas cartridges are exhausted by use, not by time on the shelf — but they can be exhausted while still feeling normal to breathe through, so follow the change schedule from your safety assessment. Never rely on smell alone: some chemicals have poor warning properties and cannot be detected by odour before the cartridge is spent. Store cartridges sealed when they are not in use, so they do not adsorb contaminants from the air. Particulate pre-filters are different: replace them when breathing becomes noticeably harder, and replace any filter that is damaged or wet at once. Keep spares on hand so a change is never put off for lack of stock.

Need a quotation? Tell us the product, the quantity and the destination country, and we will come back with a clear price. Send an inquiry or message us on WhatsApp.

Frequently asked questions

What is the difference between the 3M 6001 and the 6003?
The 6001 protects against organic vapours only — solvents and similar vapours. The 6003 protects against organic vapours and acid gases. If acid gases are present, the 6001 is not enough; if only organic vapours are present, the 6001 is the simpler choice.
What does the 60926 protect against that the 6006 does not?
The same gases — organic vapours, acid gases, ammonia and formaldehyde — plus dust. The 60926 is a combination filter rated A1B1E1K1P3: it adds a P100 particulate filter to the multi-gas cartridge, so it protects against particles as well as gases. The 6006 is gas only and needs a separate particulate pre-filter where dust is present.
What is the difference between the 6003 and the 6003CN?
The 6003CN is the China-market version of the cartridge — a different listing for the China market, not the same product as the international 6003. Order by the exact model for your market, and check the marking on the cartridge and its packaging before you accept the goods.
How do I know when to replace a gas cartridge?
Follow the change schedule from your safety assessment. Never rely on smell alone — some chemicals have poor warning properties and cannot be detected by odour before the cartridge is spent. Particulate pre-filters are different: replace them when breathing becomes noticeably harder.

Contact WAYTO TRADE CO., LIMITED by email at wttsafety@gmail.com or on WhatsApp at +86 186 0601 6519.